Darcy–Weisbach Pipe Friction Loss Calculator

Calculate straight-pipe head and pressure loss using a supplied Darcy friction factor.

VISUAL FIELD GUIDECAD-STYLE • VECTOR

Pressure drop along the straight pipe

Measure real pipe bore and the full straight-run length; enter a Darcy friction factor for the flow regime.

CENTER → CENTERSTRAIGHT CUTTakeoff ATakeoff BNOT TO SCALE
Measurement reference only — not to scale. On mobile, swipe across the diagram.
01
Inside diameter50mm
02
Straight length30m
03
Flow120L/min
MEASURE

Measure real pipe bore and the full straight-run length; enter a Darcy friction factor for the flow regime.

COMMON ERROR

Entering a Fanning coefficient or adding fitting losses into the straight length without disclosure.

✦ INSTANT CALCULATION

Darcy–Weisbach Pipe Friction Loss Calculator

YOUR RESULT
—

ⓘ Calculated locally in your browser. Results depend on the values and units you enter.

How this calculator works

h_f = f(L/D) v²/(2g), Δp = ρgh_f. Darcy f is FOUR times the Fanning factor. Steady fully developed incompressible flow only; minor fittings/entrances are excluded. Obtain a valid f for Reynolds number and roughness. This is geometry or an estimating model, not a plumbing-code approval. Check actual component specifications and local regulations.

Formula and reasoning

Friction head (m) = Darcy f × length(m) / diameter(m) × velocity²/(2g); velocity(m/s) = [flow(L/min)/60000] / [π × (diameter(mm)/1000)² / 4], g = 9.80665 m/s².

  1. 1. Start with the measurements
    Actual inside diameter (mm)50Straight length (m)30Flow (L/min)120Darcy friction factor (not Fanning)0.025
  2. 2. Substitute into the formula

    Actual inside diameter (mm) = 50 ? Straight length (m) = 30 ? Flow (L/min) = 120 ? Darcy friction factor (not Fanning) = 0.025

  3. 3. Check the computed answer

    Result for the sample inputs0.7935 m

Worked example

At ID 50mm, 30m, 120L/min, f=0.025, water: head loss is about 0.79m.

Frequently asked questions

Where should a beginner measure?

h_f = f(L/D) v²/(2g), Δp = ρgh_f. Darcy f is FOUR times the Fanning factor. Steady fully developed incompressible flow only; minor fittings/entrances are excluded. Obtain a valid f for Reynolds number and roughness.

Does this replace pipe standards or manufacturer dimensions?

This is geometry or an estimating model, not a plumbing-code approval. Check actual component specifications and local regulations.

Results are informational and assume the stated inputs and formulas. Double-check critical financial or engineering decisions with a qualified professional.

Add this calculator to your website

Share a working calculator on your blog or website. Choose a fixed size or let the height fit the content.

Fixed height

Works on websites that accept iframe HTML.

Responsive height

Automatically adjusts the height. Your website must allow scripts.

Open calculator preview ↗

Powered by EverydayCalc